Omid Mirmosayyeb; Vahid Shaygannejad; Mahshad Afsharzadeh; Roozbeh Bataei; Nasim Nehzat; Aida Mohammadi; Mahsa Ghajarzadeh
Volume 21, Issue 4 , October 2022, , Pages 206-210
Abstract
Background: The purpose of this study was to evaluate the validity and reliability of the Persian version of Patient Determined Disease Steps (PDDS) in both patients with multiple sclerosis (MS) and neuromyelitis optica spectrum disorder (NMOSD).Methods: One hundred and forty-five patients were enrolled ...
Read More
Background: The purpose of this study was to evaluate the validity and reliability of the Persian version of Patient Determined Disease Steps (PDDS) in both patients with multiple sclerosis (MS) and neuromyelitis optica spectrum disorder (NMOSD).Methods: One hundred and forty-five patients were enrolled between May and September 2020 by consecutive sampling. Participants were asked to complete timed 25-foot walk (T25FW), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and Multiple Sclerosis Quality of Life-54 (MSQOL-54). Patients also completed Timed Up and Go (TUG) and six-minute walk (6MW) tests. Construct validity was assessed by calculating correlation between PDDS and ambulatory and demographic items. The intra-class correlation coefficient (ICC) was used to evaluate reliability.Results: One hundred and eleven patients with MS and 34 with NMOSD with disease duration of 7.6 ± 5.8 years were enrolled. Twenty-seven percent were men and mean Expanded Disability Status Scale (EDSS) was 1.8 ± 1.8.There was a significant positive correlation between EDSS and PDSS (rho = 0.64, P < 0.001) which was evident in MS subgroups and NMOSD [secondary progressive MS (SPMS): rho = 0.64, P < 0.001; relapsing-remitting MS (RRMS): rho = 0.47, P < 0.001; NMOSD: rho = 0.52, P = 0.001]. PDDS had also significant positive correlation with TUG, T25FW, and MSWS-12. PDDS had also significant negative correlation with 6MW test. PDDS had weak correlation with demographic variables. The ICC was calculated as 0.99 for PDDS.Conclusion: The Persian version of PDDS provides valid and reliable instrument to assess MS/NMOSD-related disability.
Motahareh Afrakhteh; Sara Esmaeili; Mohsen Shati; Seyedeh Fahimeh Shojaei; Maryam Bahadori; Babak Zamani; Mostafa Almasi-Doghaee; Bahram Haghi-Ashtiani
Abstract
Background: Amyotrophic Lateral Sclerosis-Specific Quality of Life-Revised (ALSSQOL-R) encompasses 50 items which assess quality of life (QOL) in patients with amyotrophic lateral sclerosis (ALS) in six major domains. This study aims to translate the ALSSQOL-R into Persian and evaluate its reliability ...
Read More
Background: Amyotrophic Lateral Sclerosis-Specific Quality of Life-Revised (ALSSQOL-R) encompasses 50 items which assess quality of life (QOL) in patients with amyotrophic lateral sclerosis (ALS) in six major domains. This study aims to translate the ALSSQOL-R into Persian and evaluate its reliability and validity among Iranian patients. Methods: ALSSQOL-R was translated by the standard multi-step forward-backward method. Content validity was calculated using item content validity index (I-CVI). Three items in the “intimacy” domain were deleted considering Iranian culture. Cronbach’s alpha was used for all 6 dimensions to calculate the internal consistency reliability. Test-retest reliability was evaluated using intraclass correlation coefficient (ICC) with one-month interval. Concurrent validity was measured by the validated version of 36-Item Short Form Health Survey (SF-36) questionnaire. Results: Sixty-three patients with ALS were enrolled in the study. I-CVI was 70%, promoted to 85% after modifications (acceptable). Regarding internal consistency reliability, Cronbach’s alpha in all six domains was ³ 0.70 and total Cronbach’s alpha was 0.89 which is assumed as good. In terms of test-retest reliability, ICC [95% confidence interval (CI)] was 0.91 (91%) and Pearson correlation coefficient (r) was 0.90 (P < 0.001), all indicating an excellent reliability. The concurrent validity was established based on a strong correlation with SF-36 (r = 0.744, P < 0.001). Conclusion: The findings show that the modified Persian version of ALSSQOL-R is a valid and reliable QOL questionnaire which can be used for Iranian patients with ALS in both clinical and research settings.